The suction head fails to take the reinforcement piece

28

2023-04

Possible Causes:

1. The height of the suction head and the reinforcing piece is not set properly

2. The feeding compensation is not set properly, and the reinforcing sheet is not peeled off properly

3. There is residual glue on the support table

4. There is a reinforcing piece on the suction head

5. The delay of taking the reinforcement film is too short


Solution:

1. Adjust the height of the suction head and the reinforcement piece

2. Adjust feed compensation setting

3. Clean the residual glue of the support table

4. Clean the suction head

5. Adjust the delay of taking the reinforcement film

Previous:Stage Imaging Failed

Return

Next:The reinforcement sheet can be erected or flipped